★ optional 95.25mm long probe or 43.25mm short probe double or four density structure, the maximum test area of 19.2"x25.6"
★ Switch card module design, according to customer needs to choose the test area
★ MASON fixture format, compatible with other mainstream brand framework fixture
★ Fixture can be X/Y fine tuning, improve PCB test yield
★ The upper mold can be turned 90 degrees, and can be moved back and forth, convenient fixture installation, debugging and maintenance
Configure density
70mil(double density);
50 mil (four density)
Maximum test area
19.2 "x 25.6" (487 mm * 650 mm)
Maximum test points
384k
Testable PCB size
150 mm * 150 mm (Min)
487 mm * 650 mm (Max)
PCB thickness
0.4~4mm (automatic)
Panel weight
<4KG
Throughput
250PCS/h(test points 40000)
The test voltage
50V~300V
Conduction impedance
10 Ω ~ 100Ω
Insulation impedance
1 m Ω ~ 100 m Ω
Carbon line test
200 Ω ~ 18K Ω, accuracy: ±10%
Buried resistance test
200 Ω ~ 200KΩ, accuracy: ±10%
Fixture specification
Mason architecture; Compatible with other formats
minimum diameter of probe: 0.15mm;
minimum theoretical probe spacing: 10mil
CAM support software
Mason independently developed CAM software MasonCam
1. MeNet (points selection software)
2. Me Fix(universal fixture production)
3. MeTab (maintenance software)
Web tabular
Mason format MXG(other format optional)
Fixture fine-tuning
Fine tuning direction: X/Y error correction accuracy: 土0.01mm
The power supply requirements
AC380V±5%, three-phase five-wire system, 50/60Hz, 9KW, 13A
Air supply requirements
Air pressure: 0.6-0.8mpa; Gas consumption: 200L/min
Environmental requirements
No dust; Temperature: 22° C ~ 25° C; Humidity: 40% ~ 60%
(1) Spark detection;
(2) Fixture fine-tuning;
(3) Edge scribing;
(4) The laser marking