Your current location: First page > Product > Multilayer board market > Quality testing solutions > Large area automatic universal testing machine
Suitable for communication equipment, server, data center and other large size products

★ optional 95.25mm long probe or 43.25mm short probe double or four density structure, the maximum test area of 19.2"x25.6"

★ Switch card module design, according to customer needs to choose the test area

★ MASON fixture format, compatible with other mainstream brand framework fixture

★ Fixture can be X/Y fine tuning, improve PCB test yield

★ The upper mold can be turned 90 degrees, and can be moved back and forth, convenient fixture installation, debugging and maintenance

The equipment parameters
  • Configure density

    70mil(double density);
    50 mil (four density)

  • Maximum test area

    19.2 "x 25.6" (487 mm * 650 mm)

  • Maximum test points

    384k

  • Testable PCB size

    150 mm * 150 mm (Min)
    487 mm * 650 mm (Max)

  • PCB thickness

    0.4~4mm (automatic)

  • Panel weight

    <4KG

  • Throughput

    250PCS/h(test points 40000)

Test parameters
  • The test voltage

    50V~300V

  • Conduction impedance

    10 Ω ~ 100Ω

  • Insulation impedance

    1 m Ω ~ 100 m Ω

  • Carbon line test

    200 Ω ~ 18K Ω, accuracy: ±10%

  • Buried resistance test

    200 Ω ~ 200KΩ, accuracy: ±10%

Application parameters
  • Fixture specification

    Mason architecture; Compatible with other formats
    minimum diameter of probe: 0.15mm;
    minimum theoretical probe spacing: 10mil

  • CAM support software

    Mason independently developed CAM software MasonCam
    1. MeNet (points selection software)
    2. Me Fix(universal fixture production)
    3. MeTab (maintenance software)

  • Web tabular

    Mason format MXG(other format optional)

  • Fixture fine-tuning

    Fine tuning direction: X/Y error correction accuracy: 土0.01mm

Environmental parameters
  • The power supply requirements

    AC380V±5%, three-phase five-wire system, 50/60Hz, 9KW, 13A

  • Air supply requirements

    Air pressure: 0.6-0.8mpa; Gas consumption: 200L/min

  • Environmental requirements

    No dust; Temperature: 22° C ~ 25° C; Humidity: 40% ~ 60%

Optional features

(1) Spark detection;
(2) Fixture fine-tuning;
(3) Edge scribing;
(4) The laser marking